  Particle Retention and Flow Rate Data

Plain Dutch Weave Filter Cloth

Mesh Count

Particle Retention

Thickness

Weight

Flow Rate Per Square Inch

 Microns

Inches

Inches

lbs./sq.ft.

Oil GPM

Fuel GPM

Air SCFM

10 x 52

325

0.0128

0.059

1.03

3.8

8.5

47

12 x 64

295

0.0116

0.048

0.76

3.7

8.3

45

14 x 88

245

0.0096

0.037

0.69

3.6

8.3

44

24 x 110

138

0.0054

0.03

0.52

3.5

7.9

43

30 x 150

102

0.0042

0.021

0.37

3.0

7.3

38

40 x 200

84

0.0033

0.016

0.27

2.5

7.2

35

30 X 150

82

0.0032

0.02

0.38

1.6

4.5

27

50 x 250

64

0.0025

0.012

0.22

1.9

6.2

33

 

Twilled Dutch Weave Filter Cloth

Mesh Count

Particle Retention

Thickness

Weight

Flow Rate Per Square Inch

 Microns

Inches

Inches

lbs./sq.ft.

Oil GPM

Fuel GPM

Air SCFM

20 x 250

74

0.0029

0.028

0.61

1.05

3.1

17

30 x 250

69

0.0027

0.028

0.64

0.90

3.0

16

80 x 700

32

0.0013

0.011

0.25

0.31

2.4

14

165 x 1400

17

0.0007

0.006

0.16

0.12

1.89

11

200 x 1400

10

0.0004

0.006

0.16

0.10

1.66

9.2

325 x 2300

5

0.0002

0.003

0.10

0.06

1.12

7.8

 
Filter Cloth Micron Rating:
This data was determined using the "bubble point" test method.  
One micron equals 0.00003937" or 0.001mm.
 
Flow Rate Data:
This data was based on a test sample one square inch in area.
Oil   - MIL-H-5606-B @ 80F (viscosity 90 SSU) at 1 psid.
Fuel - MIL-F-7024-A, Type II @ 78F (viscosity 35 SSU) at 1 psid.
Air   - Tested @ 75F at 1 psid.
 
 
[Technical Reference Index]      [Woven Wire Main Index]      [Woven Wire Mesh Products]
By using this website, you are agreeing that you have read and accepted the Terms of Use Agreement
If you do not agree to these terms, please do not use this website.
Copyright 2015  Screen Technology Group, Inc.   All Rights Reserved.

Last modified: August 28, 2016